York 031-02932-033逻辑板

发布时间:2026-10-12人气:
  • York 031-02932-033逻辑板
  • York 031-02932-033逻辑板
  • York 031-02932-033逻辑板

York 031-02932-033逻辑板 

1.产 品 资 料 介 绍:

York 031-02932-033 逻辑板
产品特点
实时采集机组压力温度等工艺信号完成逻辑运算
内置多重保护逻辑实现过载超温欠压自动停机防护
板载通讯接口可与机组主控系统双向数据交互
防浪涌电路设计抵御控制柜内电磁干扰
标准 PCB 板卡结构便于冷水机组控制柜替换检修
产品应用领域
约克离心式冷水机组控制系统
大型商用中央空调制冷主机
工业冷冻压缩机控制柜
数据中心冷却机组控制单元
工厂工艺冷水系统
商场楼宇暖通制冷设备
医院中央空调主机系统
轨道交通制冷配套机组
洁净车间恒温冷水设备
大型酒店暖通制冷主机
产品参数
信号采集多路温度压力模拟信号
通讯方式机组内部总线通讯
安装形式机柜固定式板卡装配
York 031-02932-033 逻辑板作为约克冷水机组核心逻辑控制组件负责机组运行判断保护联锁与信号传输保障制冷主机安全稳定运行

York 031-02932-033逻辑板 产品英文介绍

York 031-02932-033 Logic Board

Product Features

Real time collection of process signals such as unit pressure and temperature to complete logical operations

Built in multiple protection logic for automatic shutdown protection against overload, overheating, and undervoltage

The onboard communication interface can exchange bidirectional data with the main control system of the unit

Anti surge circuit design to resist electromagnetic interference inside the control cabinet

The standard PCB board structure facilitates the replacement and maintenance of the chiller control cabinet

Product application areas

York centrifugal chiller control system

Large commercial central air conditioning refrigeration unit

Industrial refrigeration compressor control cabinet

Control unit for data center cooling unit

Factory Process Cold Water System

HVAC and refrigeration equipment for shopping mall buildings

Hospital central air conditioning host system

Rail transit refrigeration supporting unit

Cleanroom constant temperature cold water equipment

HVAC and refrigeration mainframe for large hotels

Product Specifications

Signal acquisition of multi-channel temperature and pressure simulation signals

Communication method: Internal bus communication of the unit

Installation form: Cabinet fixed board assembly

The York 031-02932-033 logic board, as the core logic control component of the York chiller unit, is responsible for unit operation judgment, protection interlock, and signal transmission to ensure the safe and stable operation of the refrigeration host

York 031-02932-033逻辑板 产品展示

031-02932-033.webp.jpg

视频展示


其他产品

PROSOFT MVI69E-MBS 通讯模块
HIMA F8621A 安全继电器模块
UFC719AE01 串行通信扩展模块 

英文产品

BENTLY 140734-05 Thermocouple output card
 3HAC025338 Accessory drive
BENTLY 145988-01 Thermocouple input card

6415-001-N-H-K6DD1681-0AJ1TRICONEX 3703E
6415-001-G-N-K6DD1681-0AJ0TRICONEX 3604E
6415-001-C-N-N6DD1681-0AH2TRICONEX 3636R
6415-001-C-N-K6DD1681-0AH1TRICONEX 3501E
6415-001-C-M-K6DD1681-0AG2TRICONEX 3601E
6415-001-C-H-K6DD1681-0AF4TRICONEX 3805H
6410-031-N-N-N6DD1681-0AF3TRICONEX 3502E

The content is from Ruichang Mingsheng Automation Equipment Co., LTD

Contact: +86 15270269218 


推荐资讯

+86 15270269218