AMAT Applied Materials 1110-01038变压器
1.产 品 资 料 介 绍:
AMAT Applied Materials 1110-01038变压器 英文资料:
1. High-precision voltage conversion and voltage stabilization capability
As the core power hub of semiconductor equipment, the core advantage of the 1110-01038 transformer lies in the power supply accuracy adapted to the micron-level process. Referring to the technical standards for semiconductor-specific transformers, it is highly likely to adopt a combined structure of all-copper windings and high-magnetic induction silicon steel sheets, achieving a conversion efficiency of over 98%, and precisely matching the voltage-sensitive process requirements of etching machines, thin-film deposition equipment, etc. The built-in intelligent voltage compensation module can handle an input voltage fluctuation of ±10%, and the output voltage error is strictly controlled within ±1.5%. Combined with a 20-step fine voltage step adjustment design, it can flexibly adapt to multiple secondary voltage requirements such as 3.8V-25.3V, providing stable power input for the core components of the equipment.
Ii. Specialized Adaptation design for harsh working conditions
In view of the special environment of semiconductor factories, this transformer highlights anti-interference and cleanroom compatibility in terms of material and structure. The insulation system adopts H-class high-temperature resistant materials (with a temperature resistance of 180℃), and is combined with dual shielding technology - the combination of copper foil electrostatic shielding and magnetic shielding layers, which can achieve a harmonic isolation efficiency of over 95%, and the total harmonic distortion rate (THD) is less than 3%, effectively blocking the influence of power grid surges and electromagnetic interference on the PLC control system. The protection grade is expected to reach IP45 or above, with dust-proof and moisture-proof capabilities. At the same time, it adopts an oil-free dry structure design to prevent oil leakage and contamination of the cleanroom environment, meeting the strict requirements of cleanrooms of grade 10 or above. The wide temperature working range covers -15 ℃ to 40℃, which can adapt to the environmental differences of factories in different regions.
Iii. Highly Adaptable Installation and Integration System
To be compatible with the full range of AMAT semiconductor devices, the 1110-01038 adopts a modular and compact design. The installation dimensions fully take into account the equipment integration requirements, supporting both wall-mounted and floor-standing dual-posture installation, which is suitable for the space limitations of the high-density layout in semiconductor factories. The input side is compatible with the standard industrial power grid of 380V/50Hz. The output side can be flexibly configured according to the load requirements. Meanwhile, an EtherCAT communication interface is reserved, which can be seamlessly integrated with the AMAT FabWorks production execution system to achieve real-time monitoring and remote diagnosis of parameters such as voltage and current. In addition, the product design strictly adheres to the principle of interchangeability. The installation holes and coil parameters are compatible with the older models of the same series, significantly reducing the cost of equipment upgrades and renovations.
Iv. Comprehensive Security Protection Mechanism
Based on the high security requirements of semiconductor equipment, this transformer has established a multi-level intelligent protection system. The hardware level integrates triple protection circuits for overcurrent, overload and short circuit, with a response time of less than 20 milliseconds. When abnormal current is detected, the power supply link can be instantly cut off. A dedicated circuit breaker switch is installed on the input side, which has the functions of immediate power-off in case of overload and maintenance safety interlock to prevent risks caused by unauthorized operations. In terms of insulation performance, the insulation resistance is greater than 100MΩ. It can withstand the strict withstand voltage test and short-circuit test, and complies with the SEMI S2 equipment safety standard. It is also equipped with a built-in temperature monitoring sensor. When the winding temperature rise exceeds the specified value, it will automatically trigger heat dissipation enhancement or shutdown protection.
AMAT Applied Materials 1110-01038变压器 产品展示
产品视频
3.其他产品
KOLLMORGEN CP310250 PRD-P310250Z-55 伺服驱动器
Schneider 140CPS11100模拟输入模块
Schneider 140CPU43412A 控制器模块
4.其他英文产品
VMIVME-2536 Gas turbine module
BENTLY 3500/33 149986-01 Monitor module
SST-1500-YCX-3-1-0 Communication module
SRF3632-5265-84-5-56BC-CU | SC403-002 | SC752A-001-01 |
SRF3632-5227-84-5-56BC-CU | SC403-013 | SC753A-010-02 |
SR5348-4592-45B | SC403-012-T2 | SC943T200101 |
SR5340-5370-4-45B | SC403-004-T3 | SC903NN-033-01 |
SR489-P5-HI-A20 | SC402-037-T3 | SC903AN-001-01 |
SR489-CASE | SC403-002-T4 | SC904NN-001-01 |
SR469-P5-LO-A20-T | SC402-011-T3 | SC933-050-01 |
The content is from Ruichang Mingsheng Automation Equipment Co., LTD