AMAT Applied Materials 0100-00985智能接口组件板
1.产 品 资 料 介 绍:
- 跨模块信号转换:将传感器模拟信号(如温度 4-20mA)转为数字信号,传输至控制器优化工艺参数。
- 总线协议适配:实现 PLC 与射频匹配组件(如 0041-78374)的 Profinet 协议通信,保障指令实时下发。
- 设备状态汇总:采集气缸、互锁模块等组件状态数据,统一上传至 HMI,便于运维人员监控。
- 安装:固定于电控柜 DIN 导轨,屏蔽线单端接地(≤0.5Ω),远离射频电源模块。
- 维护:每 3 个月检查网口 / 端子接触状态,每 6 个月备份协议配置参数,故障优先排查协议地址冲突。
- 采购:优先选原厂供应商(如赛米卡尔电子),到货验证协议兼容性测试报告与序列号溯源。
AMAT Applied Materials 0100-00985智能接口组件板 英文资料:
1、 Core positioning
AMAT 0100-00985 is a "multi protocol signal interaction hub" for semiconductor equipment, responsible for integrating analog/digital signals, converting industrial bus protocols (such as Modbus, Profinet), achieving efficient data exchange between controllers, sensors, and actuators, and adapting to Class 100 clean environments and high-frequency electromagnetic interference scenarios.
2、 Key parameters
Category
Specifications
Interface type
4-channel RS-485, 2-channel Ethernet, 8-channel digital I/O, 4-channel analog I/O
Protocol compatibility
Supports Modbus RTU, Profinet, TCP/IP protocols
Data rate
Ethernet ≤ 100Mbps, RS-485 ≤ 1Mbps
Isolation characteristics
Dual isolation of power/signal, isolation voltage ≥ 2500V DC
Environmental adaptation
-10-60 ℃ IP40、 Anti EMI interference (EN 61000-6-2)
Compatibility
Compatible with AMAT 0225-01622 controller and 0100-20001 electronic interface module
3、 Core applications
Cross module signal conversion: Convert sensor analog signals (such as temperature 4-20mA) into digital signals and transmit them to the controller to optimize process parameters.
Bus protocol adaptation: Implement Profinet protocol communication between PLC and RF matching components (such as 0041-78374) to ensure real-time instruction issuance.
Equipment status summary: Collect status data of components such as cylinders and interlock modules, and upload them to HMI for easy monitoring by operation and maintenance personnel.
4、 Key points of operation and maintenance
Installation: Fixed to the DIN rail of the electrical control cabinet, shielded wire with single end grounding (≤ 0.5 Ω), away from the RF power module.
Maintenance: Check the network port/terminal contact status every 3 months, backup protocol configuration parameters every 6 months, and prioritize troubleshooting protocol address conflicts.
Procurement: Prioritize the selection of original suppliers (such as Semicar Electronics), and provide compatibility testing reports and serial number traceability for the arrival verification protocol.
5、 Technical value
Multi protocol integration reduces the number of interface modules, dual isolation improves signal stability, is compatible with multi device systems, and reduces semiconductor equipment wiring and debugging costs.
AMAT Applied Materials 0100-00985智能接口组件板 产品展示
产品视频
3.其他产品
INDRAMAT TVM2.4-050-220/300-W1 电源模块
BENTLY 3500/92 133323-01 继电器模块
Bently 9200-01-02-02-00 振动速度传感器
4.其他英文产品
469-P5-HI-A20-E-H Relay module
A3120/022-000 Vibration transducer
HONEYWELL CC-PCNT02 Analog module
6ES5526-3LG11 | CACR-SR15BE12G-C | C2133 ASYST INC 3200-1045-01 3200-1065-01 |
6ES5524-3UA13 | CACR-IR1515FC | Asyst 3200-1101-02 |
6ES5521-8MA22 | CACR-TS111Z1SR, | Asyst 3200-1251-02 |
6ES5521-8MA21 | CACR-SR20BF1AM | 061-06039-0003 |
6ES5513-3LB11 | CACR-IR-USED | 60-0401-02 |
6ES5511-5AA14 | CACR-IR44SGC | 067-02513-0001 |
The content is from Ruichang Mingsheng Automation Equipment Co., LTD
Contact: +86 15270269218